Showing 65–80 of 103 results
Throughput: up to 180 tests/hour
40 sample positions, 9 reagent positions
Up to 240 cuvettes on board
Target: small and mid-size labs
Throughput: 200 tests/hour
Footprint: <0.68 m² | Throughput per area: >294 T/H/m²
72 sample positions, 20 reagent positions
Reagent area with 24-hour refrigeration
Target: small to medium-sized labs/hospitals
Throughput: 450 tests/hour (single module)
Up to 112 sample positions, 30 reagent positions
Up to 2,000 walk-away tests
Reagent area with 24-hour refrigeration
TLA (Total Laboratory Automation) connectable; multiple X6 units can be linked
Target: medium/high-volume labs
Throughput: 600 tests/hour (single module) | up to 2,400 tests/hour (4 modules combined)
300 sample positions, 42 reagent positions (RFID-enabled)
Up to 2,800 walk-away tests
Test menu: up to 278 assays
SATLARS™ Total Laboratory Automation compatible
Target: medium to large labs
Direct Measurement from EDTA Vacutainer for accurate automated ESR analysis.
Fully Automated ESR Analyzer with an in-built mixture, designed for efficient blood test equipment.
Throughput of up to 120 tests per hour, allowing high-volume testing.
Random access and batch access sample loading for flexibility in diagnostic devices.
Excellent correlation with the Westergren method, ensuring reliable results.
7” Colour TFT Touchscreen Display for user-friendly operation.
Built-in thermal printer for immediate result documentation.
Wireless LIS connectivity to streamline data management.
External USB barcode connectivity for easy sample tracking.
Optional IoT-enabled / RFID closed system to enhance operational capabilities.
Direct Measurement from EDTA Vacutainer for accurate automated ESR analysis.
Fully Automated ESR Analyzer with an in-built mixture, designed for efficient blood test equipment.
Throughput of up to 120 tests per hour, allowing high-volume testing.
Random access and batch access sample loading for flexibility in diagnostic devices.
Excellent correlation with the Westergren method, ensuring reliable results.
7” Colour TFT Touchscreen Display for user-friendly operation.
Built-in thermal printer for immediate result documentation.
Wireless LIS connectivity to streamline data management.
External USB barcode connectivity for easy sample tracking.
Optional IoT-enabled / RFID closed system to enhance operational capabilities.
Direct Measurement from EDTA Vacutainer for accurate automated ESR analysis.
Fully Automated ESR Analyzer with an in-built mixture, designed for efficient blood test equipment.
Throughput of up to 120 tests per hour, allowing high-volume testing.
Random access and batch access sample loading for flexibility in diagnostic devices.
Excellent correlation with the Westergren method, ensuring reliable results.
7” Colour TFT Touchscreen Display for user-friendly operation.
Built-in thermal printer for immediate result documentation.
Wireless LIS connectivity to streamline data management.
External USB barcode connectivity for easy sample tracking.
Optional IoT-enabled / RFID closed system to enhance operational capabilities.
Testing Range Up to 10 Parameters
Throughput Up to 120 Tests/Hr
2.8” Colour TFT Touchscreen Display
Built-in Thermal Printer
Wireless LIS Connectivity
RFID-Based Closed System
Testing Range Up to 14 Parameters
ACR & PCR Ratio
Throughput Up to 120 Tests/Hr
2.8” Colour TFT Touchscreen Display
Built-in Thermal Printer
Wireless LIS Connectivity
Wireless Barcode Connectivity
RFID-Based Closed System
Compact, fully automated 6-part differential haematology analyser designed for CBC and differential testing, including immature granulocyte (IG) analysis.
Uses fluorescent flow cytometry for WBC differentiation, with hydrodynamic focusing DC detection for RBC and platelets and a cyanide-free method for haemoglobin measurement.
Provides 28 standard parameters, including CBC, 5-part WBC differential and automated IG count.
Features open-tube sample analysis and requires only 25 µL of whole blood, making it suitable for low-volume samples
Offers throughput of up to 60 samples/hour on XN-330 and 70 samples/hour on XN-350. The XN-350 additionally supports optional RET/IPF and body-fluid applications.
Stores up to 100,000 sample results and incorporates a compact design with an integrated interface for efficient routine laboratory workflow.
Fully automated 6-part differential haematology analyser designed for routine CBC and advanced differential testing.
Uses fluorescent flow cytometry for WBC, DIFF, RET, IPF and body-fluid analysis, alongside impedance-based platelet/RBC analysis.
Offers throughput of up to 70 samples per hour for CBC and CBC + DIFF testing.
Features closed-tube analysis, reducing direct handling of blood samples during routine operation.
Requires only 25 µL of whole blood and provides automated immature granulocyte (IG) measurement with every differential analysis.
Supports advanced applications including RET/RET-He, IPF, low-WBC and body-fluid analysis, with storage for up to 100,000 sample results.
Fully automated 6-part differential haematology analyser with an integrated sampler for higher-volume routine laboratory workflows.
Offers both open- and closed-tube analysis, with a two-drawer sampler that enables continuous loading of samples.
Provides throughput of up to 70 samples per hour for CBC and CBC + DIFF, using only 25 µL of whole blood.
Uses fluorescent flow cytometry for advanced cell differentiation, including automated immature granulocyte (IG) analysis.
Supports automatic Repeat, Rerun and Reflex testing, helping reduce manual intervention and improve turnaround time.
Offers advanced applications including RET, RET-He, IRF, IPF, low-WBC and body-fluid analysis, making it suitable for broader haematology testing requirements.
Automated 3-part differential haematology analyser designed for routine CBC testing in laboratories requiring a compact system.
Provides 20 parameters in whole-blood and pre-diluted modes, including WBC, RBC, HGB, platelets and 3-part WBC differential parameters.
Delivers throughput of approximately 70 samples per hour, supporting efficient routine testing.
Requires only approximately 16 µL of whole blood, reducing sample requirements.
Uses DC detection for WBC, RBC and platelets and a non-cyanide haemoglobin analysis method for HGB.
Stores up to 500,000 patient records with histograms and provides specimen flagging to assist with interpretation of abnormal results
Fully automated 3-part hematology analyser with throughput of up to 72 whole blood samples/hour
Dual operational reagent system supports uninterrupted workflow
10.4-inch full-colour touchscreen with mouse and keyboard connectivity
High-resolution disk apertures of 100 μm for WBC and 68 μm for RBC/PLT enable precise cell counting
Volume-versus-counting technology reduces calibration frequency while maintaining accuracy
Compact footprint suited to small and mid-sized laboratories, clinics and hospitals
Provides fast, reliable routine blood analysis with minimal operational complexity.
Fully automated 3-part hematology analyser with processing capacity of up to 72 samples/hour
Dual reagent channels enable continuous and efficient workflow
Features a 10.4-inch colour touchscreen with mouse and keyboard compatibility
High-resolution apertures support precise WBC, RBC and platelet counting
Volume-versus-counting technology helps reduce calibration requirements and improve result accuracy
Compact design combines advanced hardware and software for routine hematology testing
Delivers accurate, reliable blood counts in a compact system suited to small and mid-sized laboratories.
5-part differential analyser with reticulocyte counting and 34 parameters, including RET% and RET#
Processes up to 60 samples/hour with a 10.4-inch touchscreen and internal thermal printer
Uses laser-based multidimensional cell classification and dual WBC counting modes for enhanced accuracy
Provides RBC/PLT histograms, 5-part differential scattergrams and 3D stereograms
Supports multi-user access with secure login and stores up to 200,000 records with graphics
Connectivity includes RS232, USB and Ethernet
Provides high-throughput hematology and reticulocyte analysis for clinical and research applications.
End of content
End of content
Load more