Showing 65–80 of 103 results

  • SNIBE MAGLUMI 800

    • Throughput: up to 180 tests/hour
    • 40 sample positions, 9 reagent positions
    • Up to 240 cuvettes on board
    • Target: small and mid-size labs
  • SNIBE MAGLUMI X3

    • Throughput: 200 tests/hour
    • Footprint: <0.68 m² | Throughput per area: >294 T/H/m²
    • 72 sample positions, 20 reagent positions
    • Reagent area with 24-hour refrigeration
    • Target: small to medium-sized labs/hospitals
  • SNIBE MAGLUMI X6

    • Throughput: 450 tests/hour (single module)
    • Up to 112 sample positions, 30 reagent positions
    • Up to 2,000 walk-away tests
    • Reagent area with 24-hour refrigeration
    • TLA (Total Laboratory Automation) connectable; multiple X6 units can be linked
    • Target: medium/high-volume labs
  • SNIBE MAGLUMI X8

    • Throughput: 600 tests/hour (single module) | up to 2,400 tests/hour (4 modules combined)
    • 300 sample positions, 42 reagent positions (RFID-enabled)
    • Up to 2,800 walk-away tests
    • Test menu: up to 278 assays 
    • SATLARS™ Total Laboratory Automation compatible
    • Target: medium to large labs
  • Strumed iNFLA Quick

    • Direct Measurement from EDTA Vacutainer for accurate automated ESR analysis.
    • Fully Automated ESR Analyzer with an in-built mixture, designed for efficient blood test equipment.
    • Throughput of up to 120 tests per hour, allowing high-volume testing.
    • Random access and batch access sample loading for flexibility in diagnostic devices.
    • Excellent correlation with the Westergren method, ensuring reliable results.
    • 7” Colour TFT Touchscreen Display for user-friendly operation.
    • Built-in thermal printer for immediate result documentation.
    • Wireless LIS connectivity to streamline data management.
    • External USB barcode connectivity for easy sample tracking.
    • Optional IoT-enabled / RFID closed system to enhance operational capabilities.
  • Strumed iNFLA Quick Pro

    • Direct Measurement from EDTA Vacutainer for accurate automated ESR analysis.
    • Fully Automated ESR Analyzer with an in-built mixture, designed for efficient blood test equipment.
    • Throughput of up to 120 tests per hour, allowing high-volume testing.
    • Random access and batch access sample loading for flexibility in diagnostic devices.
    • Excellent correlation with the Westergren method, ensuring reliable results.
    • 7” Colour TFT Touchscreen Display for user-friendly operation.
    • Built-in thermal printer for immediate result documentation.
    • Wireless LIS connectivity to streamline data management.
    • External USB barcode connectivity for easy sample tracking.
    • Optional IoT-enabled / RFID closed system to enhance operational capabilities.
  • Strumed iNFLA Quick Pro MX

    • Direct Measurement from EDTA Vacutainer for accurate automated ESR analysis.
    • Fully Automated ESR Analyzer with an in-built mixture, designed for efficient blood test equipment.
    • Throughput of up to 120 tests per hour, allowing high-volume testing.
    • Random access and batch access sample loading for flexibility in diagnostic devices.
    • Excellent correlation with the Westergren method, ensuring reliable results.
    • 7” Colour TFT Touchscreen Display for user-friendly operation.
    • Built-in thermal printer for immediate result documentation.
    • Wireless LIS connectivity to streamline data management.
    • External USB barcode connectivity for easy sample tracking.
    • Optional IoT-enabled / RFID closed system to enhance operational capabilities.
  • Strumed uRI Quick

    • Testing Range Up to 10 Parameters
    • Throughput Up to 120 Tests/Hr
    • 2.8” Colour TFT Touchscreen Display
    • Built-in Thermal Printer
    • Wireless LIS Connectivity
    • RFID-Based Closed System
  • Strumed uRI Quick Pro

    • Testing Range Up to 14 Parameters
    • ACR & PCR Ratio 
    • Throughput Up to 120 Tests/Hr
    • 2.8” Colour TFT Touchscreen Display
    • Built-in Thermal Printer
    • Wireless LIS Connectivity
    • Wireless Barcode Connectivity
    • RFID-Based Closed System
  • SYSMEX XN-330 / XN-350

    • Compact, fully automated 6-part differential haematology analyser designed for CBC and differential testing, including immature granulocyte (IG) analysis.
    • Uses fluorescent flow cytometry for WBC differentiation, with hydrodynamic focusing DC detection for RBC and platelets and a cyanide-free method for haemoglobin measurement. 
    • Provides 28 standard parameters, including CBC, 5-part WBC differential and automated IG count. 
    • Features open-tube sample analysis and requires only 25 µL of whole blood, making it suitable for low-volume samples
    • Offers throughput of up to 60 samples/hour on XN-330 and 70 samples/hour on XN-350. The XN-350 additionally supports optional RET/IPF and body-fluid applications. 
    • Stores up to 100,000 sample results and incorporates a compact design with an integrated interface for efficient routine laboratory workflow.
  • SYSMEX XN-450

    • Fully automated 6-part differential haematology analyser designed for routine CBC and advanced differential testing.
    • Uses fluorescent flow cytometry for WBC, DIFF, RET, IPF and body-fluid analysis, alongside impedance-based platelet/RBC analysis.
    • Offers throughput of up to 70 samples per hour for CBC and CBC + DIFF testing.
    • Features closed-tube analysis, reducing direct handling of blood samples during routine operation.
    • Requires only 25 µL of whole blood and provides automated immature granulocyte (IG) measurement with every differential analysis.
    • Supports advanced applications including RET/RET-He, IPF, low-WBC and body-fluid analysis, with storage for up to 100,000 sample results.
  • SYSMEX XN-550

    • Fully automated 6-part differential haematology analyser with an integrated sampler for higher-volume routine laboratory workflows.
    • Offers both open- and closed-tube analysis, with a two-drawer sampler that enables continuous loading of samples.
    • Provides throughput of up to 70 samples per hour for CBC and CBC + DIFF, using only 25 µL of whole blood.
    • Uses fluorescent flow cytometry for advanced cell differentiation, including automated immature granulocyte (IG) analysis.
    • Supports automatic Repeat, Rerun and Reflex testing, helping reduce manual intervention and improve turnaround time.
    • Offers advanced applications including RET, RET-He, IRF, IPF, low-WBC and body-fluid analysis, making it suitable for broader haematology testing requirements.
  • SYSMEX XQ-320

    • Automated 3-part differential haematology analyser designed for routine CBC testing in laboratories requiring a compact system.
    • Provides 20 parameters in whole-blood and pre-diluted modes, including WBC, RBC, HGB, platelets and 3-part WBC differential parameters.
    • Delivers throughput of approximately 70 samples per hour, supporting efficient routine testing.
    • Requires only approximately 16 µL of whole blood, reducing sample requirements.
    • Uses DC detection for WBC, RBC and platelets and a non-cyanide haemoglobin analysis method for HGB.
    • Stores up to 500,000 patient records with histograms and provides specimen flagging to assist with interpretation of abnormal results
  • Trivitron Cellenium 21

    • Fully automated 3-part hematology analyser with throughput of up to 72 whole blood samples/hour
    • Dual operational reagent system supports uninterrupted workflow
    • 10.4-inch full-colour touchscreen with mouse and keyboard connectivity
    • High-resolution disk apertures of 100 μm for WBC and 68 μm for RBC/PLT enable precise cell counting
    • Volume-versus-counting technology reduces calibration frequency while maintaining accuracy
    • Compact footprint suited to small and mid-sized laboratories, clinics and hospitals
    • Provides fast, reliable routine blood analysis with minimal operational complexity.
  • Trivitron Cellenium 21+

    • Fully automated 3-part hematology analyser with processing capacity of up to 72 samples/hour
    • Dual reagent channels enable continuous and efficient workflow
    • Features a 10.4-inch colour touchscreen with mouse and keyboard compatibility
    • High-resolution apertures support precise WBC, RBC and platelet counting
    • Volume-versus-counting technology helps reduce calibration requirements and improve result accuracy
    • Compact design combines advanced hardware and software for routine hematology testing
    • Delivers accurate, reliable blood counts in a compact system suited to small and mid-sized laboratories.
  • Trivitron Cellenium 5D Retic

    • 5-part differential analyser with reticulocyte counting and 34 parameters, including RET% and RET#
    • Processes up to 60 samples/hour with a 10.4-inch touchscreen and internal thermal printer
    • Uses laser-based multidimensional cell classification and dual WBC counting modes for enhanced accuracy
    • Provides RBC/PLT histograms, 5-part differential scattergrams and 3D stereograms
    • Supports multi-user access with secure login and stores up to 200,000 records with graphics
    • Connectivity includes RS232, USB and Ethernet
    • Provides high-throughput hematology and reticulocyte analysis for clinical and research applications.

End of content